安徽省合肥市 周一至周六 08:30 - 18:00
Sales Hotline +86 551 6558 9290
R1336mzz(E)

R1336mzz(E) trans-1,1,1,4,4,4-hexafluoro-2-butene Refrigerant · Technical Data Sheet (TDS)

HFO-1336mzz(E), Solstice 1336mzz, hexafluoro-2-butene

View Product Details
Chemical Name反式-1,1,1,4,4,4-六氟-2-丁烯
Molecular FormulaCF₃CH=CHCF₃
CAS No.692878-73-8
Product CategoryHFO
Safety ClassA1 (Non-toxic, Non-flammable)

Product Overview

HFO-1336mzz(E) low-pressure, zero-ODP working fluid suited to high-temperature heat pumps, blowing-agent substitution and ORC.

Physical & Chemical Properties

R1336mzz(E) Refrigerant Physical & Chemical Properties
Chemical Name反式-1,1,1,4,4,4-六氟-2-丁烯
Molecular FormulaCF₃CH=CHCF₃
Molecular Weight164.05
Boiling Point (101.3 kPa)33.4 ℃ (liquid at room temperature)
Critical Temperature171 ℃
Critical Pressure2.76 MPa
Vapor Density (air = 1)about 5.7
UN Number3163
ODP (Ozone Depletion Potential)0
ASHRAE Safety ClassA1 (Non-toxic, Non-flammable)

Quality Specification

R1336mzz(E) Refrigerant Quality Specification
AppearanceColorless, transparent, free of turbidity
OdorOdorless
Purity≥ 99.9 %
Moisture≤ 10 ppm
Acidity (as HCl)≤ 1 ppm
Evaporation Residue≤ 0.01 %

Package Specification

R1336mzz(E) Refrigerant Package Specification
10/13.6 kgDisposable steel cylinder
400/800/926 kgRefillable steel cylinder
24 tISO Tank

Product Features

  • 1Zero ozone depletion potential (ODP), environmentally friendly
  • 2Relatively high boiling point (33.4℃), suited to high-temperature heat pumps
  • 3ASHRAE safety group A1: non-flammable and low toxicity
  • 4Low-pressure blowing-agent and solvent substitute

Applications

  • 1High-temperature heat pumps and industrial waste-heat recovery
  • 2Environmentally preferable low-pressure blowing-agent substitute
  • 3Working fluid for Organic Rankine Cycle (ORC) power generation
  • 4Special thermodynamic systems insensitive to temperature glide

Safety & Precautions

Safety Notice

R1336mzz(E) is a pressurized liquefied gas; although A1 non-flammable, handle only with adequate ventilation to prevent oxygen displacement in confined spaces. Avoid strong oxidizers.

Storage & TransportationStore in a cool, well-ventilated warehouse away from fire and heat sources. Keep separated from oxidizers and acids. Cylinders must be periodically inspected.

This Technical Data Sheet (TDS) is provided by Kelvins Data are based on current product standards and Wulachem’s finished-product technical references, for reference only; actual parameters are subject to the factory inspection report. For the official MSDS/SDS or batch inspection report, please contact us.

Need a refrigerant quote or selection advice?

After submitting your request, our technical consultant will contact you within 2 hours with model recommendations and the latest prices.

Inquiry +86 551 6558 9290