安徽省合肥市 周一至周六 08:30 - 18:00
Sales Hotline +86 551 6558 9290
R227ea

R227ea Heptafluoropropane Refrigerant · Technical Data Sheet (TDS)

HFC-227ea, 1,1,1,2,3,3,3-Heptafluoropropane

View Product Details
Chemical Name1,1,1,2,3,3,3-Heptafluoropropane
Molecular FormulaCF₃CHFCF₃
CAS No.431-89-0
Product CategoryHFC
Control ClassF-gas (high GWP, regulated under F-Gas)
Safety ClassA1 (Non-toxic, Non-flammable)

Product Overview

R227ea (1,1,1,2,3,3,3-heptafluoropropane) is non-flammable and non-toxic with a boiling point of -16.4℃. It is widely used in gaseous fire suppression (FM-200) and also in -70℃ low-temperature freezers and cascade systems.

Physical & Chemical Properties

R227ea Refrigerant Physical & Chemical Properties
Chemical Name1,1,1,2,3,3,3-Heptafluoropropane
Molecular FormulaCF₃CHFCF₃
Molecular Weight170.03
Boiling Point (101.3 kPa)-16.4 ℃
Critical Temperature101.9 ℃
Critical Pressure2.93 MPa
ODP (Ozone Depletion Potential)0
GWP (Global Warming Potential)3350
ASHRAE Safety ClassA1 (Non-toxic, Non-flammable)
Vapor Density (air = 1)5.869
Liquid Density (20/4℃)1.4084
Critical Density (g/cm³)0.5942
Acentric Factor0.3576
Triple Point Temperature (°C)-126.800

Quality Specification

R227ea Refrigerant Quality Specification
AppearanceColorless, transparent, free of turbidity
Purity≥ 99.9 %
Moisture≤ 10 ppm
Acidity (as HCl)≤ 1 ppm
Evaporation Residue≤ 0.01 %
Executing StandardCompliant with national and industry standards

Package Specification

R227ea Refrigerant Package Specification
5 / 10 kgDisposable steel cylinder
40 / 100 kgRefillable steel cylinder

Product Features

  • 1Non-flammable, non-toxic (A1) for high safety
  • 2Boiling point -16.4℃, for medium-low temp
  • 3Mainstream clean-agent fire suppression (FM-200)
  • 4Purity ≥99.9%

Applications

  • 1Gaseous fire suppression (clean agent)
  • 2-70℃ low-temp freezers and cascade systems
  • 3Data center and server-room fire protection
  • 4Specific process cooling

Safety & Precautions

Safety Notice

R227ea is non-flammable but has a high GWP. Both fire and refrigeration uses must recover per code and avoid emission.

Storage & TransportationStore in a cool, well-ventilated warehouse away from fire and heat; temperature not above 52℃. Keep separated from oxidizers and acids. Inspect cylinders periodically and handle gently.

This Technical Data Sheet (TDS) is provided by Kelvins Data are based on current product standards and Wulachem’s finished-product technical references, for reference only; actual parameters are subject to the factory inspection report. For the official MSDS/SDS or batch inspection report, please contact us.

Need a refrigerant quote or selection advice?

After submitting your request, our technical consultant will contact you within 2 hours with model recommendations and the latest prices.

Inquiry +86 551 6558 9290