安徽省合肥市 周一至周六 08:30 - 18:00
Sales Hotline +86 551 6558 9290
R452A

R452A HFC/HFO Blend Refrigerant (transport refrigeration) · Technical Data Sheet (TDS)

Opteon XL55, HFC/HFO blend

View Product Details
Chemical Name制冷剂 R452A(HFC/HFO 混合物)
Molecular Formula
CAS No.混合物(组分 CAS 见 SDS 第3部分)
Product CategoryHFC/HFO Blend
Safety ClassA1 (Non-toxic, Non-flammable)

Product Overview

R452A low-GWP A1 non-flammable blend for transport refrigeration and commercial cold storage, alternative to R404A.

Physical & Chemical Properties

R452A Refrigerant Physical & Chemical Properties
Chemical Name制冷剂 R452A (HFC/HFO 混合物)
Molecular Weight92.99
Boiling Point (101.3 kPa)-47.7 ℃
Critical Temperature81.3 ℃
Critical Pressure4.48 MPa
Vapor Density (air = 1)heavier than air
Composition (mass ratio)R-32 / R-125 / R-1234yf (11.0 / 59.0 / 30.0)
UN Number3161
ODP (Ozone Depletion Potential)0
GWP (Global Warming Potential)2140 (AR4)
ASHRAE Safety ClassA1 (Non-toxic, Non-flammable)

Quality Specification

R452A Refrigerant Quality Specification
AppearanceColorless, transparent, free of turbidity
OdorOdorless
Purity≥ 99.9 %
Moisture≤ 10 ppm
Acidity (as HCl)≤ 1 ppm
Evaporation Residue≤ 0.01 %

Package Specification

R452A Refrigerant Package Specification
10/13.6 kgDisposable steel cylinder
400/800/926 kgRefillable steel cylinder
24 tISO Tank

Product Features

  • 1Low GWP (2140), reduced emissions vs R404A
  • 2ASHRAE safety group A1: non-flammable and non-toxic
  • 3Suited to transport and commercial refrigeration
  • 4Alternative to R404A per equipment manufacturer specification

Applications

  • 1Transport refrigeration: reefer trucks, containers
  • 2Supermarket and cold-storage commercial refrigeration
  • 3Condensing units and chillers
  • 4Retrofit and replacement of R404A / R507 systems

Safety & Precautions

Safety Notice

R452A is a pressurized liquefied gas (UN 3161). Although A1 non-flammable, ensure adequate ventilation to prevent oxygen displacement in confined spaces.

Storage & TransportationStore in a cool, well-ventilated warehouse away from fire and heat; temperature not above 52℃. Keep separated from oxidizers and acids. Cylinders must be periodically inspected.

This Technical Data Sheet (TDS) is provided by Kelvins Data are based on current product standards and Wulachem’s finished-product technical references, for reference only; actual parameters are subject to the factory inspection report. For the official MSDS/SDS or batch inspection report, please contact us.

Need a refrigerant quote or selection advice?

After submitting your request, our technical consultant will contact you within 2 hours with model recommendations and the latest prices.

Inquiry +86 551 6558 9290