Chemical Name制冷剂 R512A(2,3,3,3-四氟丙烯与1,1,1,2-四氟乙烷混合物)
Molecular Formula
CAS No.混合物(组分 CAS 见 SDS 第3部分)
Product CategoryHFC/HFO Blend
Safety ClassA2 (Low toxicity, Flammable)

Product Overview

R512A very-low-GWP A2 flammable blend for medium-temperature refrigeration as R134a alternative.

Physical & Chemical Properties

R512A Refrigerant Physical & Chemical Properties
Chemical Name制冷剂 R512A (2,3,3,3-四氟丙烯与1,1,1,2-四氟乙烷混合物)
Molecular Weightabout 112.1 (estimated)
Boiling Point (101.3 kPa)about -29 ℃ (estimated value)
Critical Temperatureabout 96 ℃ (estimated value)
Critical Pressureabout 3.60 MPa (estimated value)
Vapor Density (air = 1)3.9
Composition (mass ratio)R-134a / R-152a (5.0 / 95.0)
UN Number3161
ODP (Ozone Depletion Potential)0
GWP (Global Warming Potential)196 (AR4)
ASHRAE Safety ClassA2 (Low toxicity, Flammable)

Quality Specification

R512A Refrigerant Quality Specification
AppearanceColorless, transparent, free of turbidity
OdorOdorless
Purity≥ 99.9 %
Moisture≤ 10 ppm
Acidity (as HCl)≤ 1 ppm
Evaporation Residue≤ 0.01 %

Package Specification

R512A Refrigerant Package Specification
10/13.6 kgDisposable steel cylinder
400/800/926 kgRefillable steel cylinder
24 tISO Tank

Product Features

  • 1Very low GWP (196), greatly reduced emissions vs R134a
  • 2ASHRAE safety group A2: flammable, fire prevention required
  • 3R-152a rich blend suited to medium-temperature refrigeration
  • 4Low-GWP alternative to R134a (per equipment approval)

Applications

  • 1Medium-temperature commercial and industrial refrigeration
  • 2Low-GWP retrofit of R134a systems
  • 3Condensing units and chillers
  • 4Refrigeration scenarios with strict environmental compliance

Safety & Precautions

Safety Notice

R512A is an A2 flammable refrigerant. No open flames or sparks in the handling area; ensure good ventilation. Cut power and increase ventilation on leakage.

Storage & TransportationStore in a cool, well-ventilated flammable-liquid warehouse away from fire, heat and oxidizers. Cylinders must be periodically inspected.

This Technical Data Sheet (TDS) is provided by Kelvins Data are based on current product standards and Wulachem’s finished-product technical references, for reference only; actual parameters are subject to the factory inspection report. For the official MSDS/SDS or batch inspection report, please contact us.