安徽省合肥市 周一至周六 08:30 - 18:00
Sales Hotline +86 551 6558 9290
R600a

R600a Isobutane Refrigerant · Technical Data Sheet (TDS)

Isobutane

View Product Details
Chemical NameIsobutane
Molecular FormulaC₄H₁₀
CAS No.75-28-5
UN NumberUN 1969
Product CategoryHC (Natural)
Control ClassHydrocarbon (natural refrigerant)
Safety ClassA3 (Flammable)

Product Overview

R600a (isobutane) is the mainstream natural refrigerant for domestic refrigerators. With a boiling point of -11.7℃ and a GWP of only about 3, it offers high efficiency and small charge for household and small commercial cooling.

Physical & Chemical Properties

R600a Refrigerant Physical & Chemical Properties
Chemical NameIsobutane
Molecular FormulaC₄H₁₀
Molecular Weight58.12
Boiling Point (101.3 kPa)-11.7 ℃
Critical Temperature134.7 ℃
Critical Pressure3.64 MPa
ODP (Ozone Depletion Potential)0
GWP (Global Warming Potential)3
ASHRAE Safety ClassA3 (Flammable)
Vapor Density (air = 1)2.006
Liquid Density (20/4℃)0.5569
Critical Density (g/cm³)0.2255
Acentric Factor0.1835
Triple Point Temperature (°C)-159.420

Quality Specification

R600a Refrigerant Quality Specification
AppearanceColorless, transparent, free of turbidity
Purity≥ 99.9 %
Moisture≤ 10 ppm
Acidity (as HCl)≤ 1 ppm
Evaporation Residue≤ 0.01 %
Executing StandardCompliant with national and industry standards

Package Specification

R600a Refrigerant Package Specification
3 / 6 kgDisposable steel cylinder
13.6 kgRefillable steel cylinder

Product Features

  • 1Natural refrigerant with ODP=0 and very low GWP (about 3)
  • 2Boiling point -11.7℃, mainstream domestic-fridge fluid
  • 3High efficiency and small charge, economical operation
  • 4Purity ≥99.9% with strict moisture control

Applications

  • 1Domestic refrigerators and freezers
  • 2Small commercial display cabinets
  • 3Minibars and wine coolers
  • 4Low-speed and laboratory small equipment

Recommended Lubricant

Must be compatible with mineral / POE oil

Safety & Precautions

Safety Notice

R600a is an A3 flammable fluid. Design per flammable-refrigerant codes; appliances must be explosion-proof with good ventilation; never charge large amounts in enclosed spaces.

Storage & TransportationStore in a cool, ventilated, explosion-proof warehouse away from fire and heat; temperature not above 52℃. Strictly separate from oxidizers. Inspect cylinders periodically and handle gently.

This Technical Data Sheet (TDS) is provided by Kelvins Data are based on current product standards and Wulachem’s finished-product technical references, for reference only; actual parameters are subject to the factory inspection report. For the official MSDS/SDS or batch inspection report, please contact us.

Need a refrigerant quote or selection advice?

After submitting your request, our technical consultant will contact you within 2 hours with model recommendations and the latest prices.

Inquiry +86 551 6558 9290